Emergency Lighting Testing

Mondial are an experienced Emergency lighting testing and installation company who offer a full one stop shop – from supplies of all types of Emergency lighting through to the design, installation, testing and certification.

Coverage

Whilst Mondial has its head office based in Leeds our qualified testing engineers are located throughout the whole of the UK mainland

Working Standards

Mondial use our own qualified testing engineers and work to British standard BS 5266. This standard recommends the provision of horizontal illumination at floor level along the centre line of a defined escape route (permanently unobstructed) not less than 1 lux and 0.5 lux for anti-panic areas, to exclude a 0.5m border around the route. In addition, for escape routes of up to 2m wide, 50% of the route width should be lit to a minimum of 1 lux. 

The actual degree of illumination should be closely related to the nature of both the premises and its occupants, with special consideration being given to care homes for the elderly, hospitals and potentially crowded venues.

Costs and Rates

Our charging system is very transparent as we agree a fixed schedule of rates in advance. When completing any Emergency lighting testing Mondial will adhere to an agreed remedial limit in order to pass off the site with a first fix. However for larger remedial works Mondial will provide a quotation for your approval.

Request This Service

Need Emergency Lighting Testing?
0113 258 0538

Do you need this service? Give our helpful team a call on the number above, or fill in our simple call request form below and we will be in touch at a time convienient to you.

F.A.Q.

Frequent Emergency Lighting Testing
Questions

u

What is a 3 hour emergency light test?

The annual test – That means if the emergency lights  battery backup should provide 3 hours of illumination. The emergency lighting needs to be tested for the full 3 hours to ensure they’re still working at the end of the test.

u

Are emergency lights always on?

There are two key types of emergency lighting: maintained and non-maintained. Maintained emergency lights stay on constantly at all times and stay lit for the minimum emergency duration (usually 3 hours) after a mains failure. … Non-maintained emergency lights are likely to be found in offices, shops and factories and only illuminate when a mains failure occurs.

u

How long should emergency lights be tested for?

3 hours Annual Test.

You must schedule a full test of your emergency lighting solutions at least once every year. If your system is supposed to give you three full hours of light when the mains power goes off, the test has to last for at least three hours. Mondial also recommend a 1 hour test every 6 months.

u

How much is emergency light testing?

Emergency Lighting Testing prices vary dependant on  the number of Emergency luminaries you have in the building .Cost savings may apply when Emergency Lighting Testing is booked together with PAT Testing and/or EICR testing.